Turbo Outlet Temperature Calculator

See Adiabatic Processes for theory and equations. Fill in appropriate values and click on 'Calculate'.

NOTE: These calculators were originally developed many years ago in Internet Explorer.

For those of you with IE 7 (or beyond), you may get a warning about my web site using ActiveX controls. It does not. I do use JavaScript for my calculators. If you want the functionality of the calculators, allow "ActiveX" controls (see instructions by clicking on the IE bar above my web page, if it is there).


Input Temperature ºF (under-hood temperature)
Input pressure psi (use absolute pressure: -0.5 psi/1000 ft elevation)
Output pressure psi (gauge pressure: usually 1-2 psi more than plenum pressure)
Compressor efficiency % (typically 60-75%)

Output temperature Pressure ratio Density ratio


Intercooler Outlet Temperature and Pressure Calculator

Fill in appropriate values and click on 'Calculate'. Calculating the turbo outlet temperature will assign that value to the IC input temperature and clear the "output" fields. If the turbo outlet DR is not calculated, the IC DR will be 0.

IC input temperature ºF (Turbo discharge temperature)
IC Efficiency percent (example: enter 80 for 80%)
IC pressure loss psi (greater than or equal to 0)
Ambient temperature ºF (outside air temperature)

Plenum temperature Overall pressure ratio Overall density ratio



Convert   ºC to ºF
Convert   ºF to ºC


Back Home Forward
Except for the small gif and jpg images, the content, images, photographs, text, and multimedia displayed are Copyright ©2000-2002 by Jeff Lucius and K2 Software. All rights reserved. No part, section, image, photo, article, or whole of this site may be reposted or redisplayed without permission of the author.